Technical Data
6.4.2. Performance features from the point of view of the entire
system
Connection module on left (ME02, ME03)
The connection module on left is electrically passive
logical no process image, therefore no address is required
mechanical ME02 - 47 mm installation dimension
ME03 - 56 mm installation dimension
electrical no power consumption
fluid left restriction of the valve block, left feed
Connection module in middle (ME02, ME03)
The intermediate feed is electrically passive
logical no process image, therefore no address is required
mechanical ME02 - 33 mm add-on dimension
ME03 - 42 mm add-on dimension
electrical no power consumption
fluid additional feed
Connection module on right
The connection module on right is electrically passive
logical no process image, therefore no address is required
mechanical ME02 - 47 mm installation dimension
ME03 - 56 mm installation dimension
electrical no power consumption
fluid right restriction of the valve block, right feed