User guide

21
Installation and commissioning
1
4
3
2
flow direction
Install the S020 fitting on the pipe.
Install the seal (mark 3“Fig. 12”) on the S020 fitting.
Make sure that the polarizing pin (mark 4 “Fig. 12”) is
on the fitting.
Insert the device (mark 1, “Fig. 12”) into the fitting.
Position the device in order the arrow on the side of
the housing indicates the direction of the flow: the
totalizers will increment.
Tighten by hand the clamp collar (mark 2 “Fig. 12”).
Charge the pipe to make sure the installation is tight.
Fig. 12: Installation into the pipe of a 8045 with a clamp connection
7.3. Wiring
danger
Risk of injury due to electrical voltage.
• Shut down the electrical power source of all the conductors and isolate it before carrying out work on the
system.
Observe all applicable accident protection and safety regulations for electrical equipment.
note
The device is not tight if at least one cable gland is not used
Seal the unused cable gland with the supplied stopper gasket:
Loosen the nut of the unused cable gland.
Remove the transparent disk.
Insert the supplied stopper gasket.
Screw the nut of the cable gland.
English