Owner's manual
8
Technical data
Type 8045
Type of fluid Conditions
Fluid group 2 par. 1.3.a
DN ≤ 32
or DN > 32 and PNxDN ≤ 1000
Fluid group 1 par. 1.3.b PNxDN ≤ 2000
Fluid group 2 par. 1.3.b
DN ≤ 200
or PN ≤ 10
or PNxDN ≤ 5000
6.3. Mechanical data
Part
Material (8045 with
flow sensor in PVDF)
Material (8045
with flow sensor in
stainless steel)
Housing / seal PC / NBR Black PPA / NBR
Cover with lid /
seal
PC / silicone PSU / silicone
Front foil Polyester
M20x1,5 cable
glands / seal
PA / neoprene
Screws Stainless steel
Nut PC PPA
Flow sensor
(exposed to the
fluid)
PVDF Stainless steel 316L
(DIN 1.4404)
Part
Material (8045 with
flow sensor in PVDF)
Material (8045
with flow sensor in
stainless steel)
Seal FKM 8045 with a G2" nut:
FKM
Earth ring of the
flow sensor
Stainless steel 316L
(DIN 1.4404) or Alloy
C22
-
Electrodes holder - PEEK
Electrodes Stainless steel 316L (DIN 1.4404) or Alloy
C22
6.4. General data
Min. fluid conductivity 20 µS/cm
Fluid temperature
• 8045 with flow sensor
in PVDF
• 8045 with flow sensor in
stainless steel
The fluid temperature may be
restricted by the fluid pressure, the
material the flow sensor is made of
and the material the S020 fitting used
is made of.
• 0 to +80 °C
• -15 to +110 °C
English