Instruction Manual
12 - 01 ATEX 2173
english
Coils suitable for individual and block assembly.
Coil dimensions
Approval code:
PD87 Ex ia IIC T6, assembly as individual device
PD91 Ex ia IIC T6, in block assembly
PE33 Ex ia IIC T5, assembly as individual device
PE34 Ex ia IIC T5, in block assembly
PE89 Ex ia IIC T4, in block assembly
Electrical connection:
JC09 Impressed single wires 0.2 mm2 (AWG 24)
JF79 Circular connector M8
JF80 Rectangular connector 2-pole
JF82 Rectangular connector 2-pole without protective collar
Overview table for use in temperature class T6
nOTE
The max. permissible power consumption depends on the max.
ambient temperature, the temperature class and the type of
assembly. These values can be taken from the above table.
18 10 22 10
Temp.
class
Max.permissible
ambient temp.
range [°C]
Assembly
Max. permissible
power consump-
tion [W]
Ignition
protection
type
Gas-
group
T6
-40 to +45
Block
assembly
0,4
Ex ia IIC
-40 to +40 0,5
-40 to +55
Indi-
vidual
0,4
-40 to +50 0,5
-40 to +45 0,7
-40 to +40 0,8