Operating principle 2/2-way valve:
A
(NC)
2/2-way valve,
direct-acting, normal output A
unloaded
Type of protection: IP65 in accordance with DIN EN 60529 / IEC
60529 with correctly connected and installed
device socket, e.g. Bürkert Type 2508
Ambient temperature: max. +55 °C
Permitted medium temperature depending on seal material and
coil model:
Seal material Model with High-power
coil or rectifier AC/DC*
Model without elec-
tronics 50 Hz, 60 Hz*
NBR -10 ... +80 °C -10 ... +80 °C
FKM 0 ... +90 °C 0 ... +120 °C
EPDM -30 ... +90 °C -30 ... +100 °C
* Type label information
Permitted media depending on seal material:
Seal material Permitted media
NBR Neutral media, compressed air, water, hydraulic oil
FKM Per-solutions, hot oils
EPDM Oil and grease-free media e.g. hot water
Operating duration
Unless otherwise indicated on the type label, the solenoid system is
suitable for continuous operation.
For the model with a high-power coil a maximum of 6 switching opera-
tions per minute is possible. This concerns devices with the following
power (type label information):
80/6 W 90/7 W 100/9 W
120/8.5 W 120/10 W 130/9 W
Important information for functional reliability during
continuous operation: If standstill for a long period at least
1-2 activations per day are recommended.
Service life
High switching frequency and high pressures reduce the service life.
english
6
4.2 Conformity
In accordance with the EC Declaration of conformity, Type 0290 is com-
pliant with the EC Directives.
4.3 Standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC-Type Examination Certificate and / or the EC
Declaration of Conformity.
4.4 Type label (Example)
0290 A 20,0 FKM VA
Made in Germany
00153212
W1Y LU
230 V 50 Hz 16 W
G 3/4 P
N 0 - 16 bar
Type
Operating prinziple
Orifice
Seal material
Body material
Identification number
Manufacturer code
Voltage, Frequency,
Power consumption
Port connection,
pressure range
5 INSTALLATION
5.1 Safety instructions
DANGER!
Risk of injury from high pressure in the equipment!
Before loosening the pipes and valves, turn off the pressure and
vent the pipes.
Risk of injury due to electrical shock!
Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation!
Observe applicable accident prevention and safety regulations for
electrical equipment!
WARNING!
Risk of injury from improper installation!
Installation may be carried out by authorized technicians only and
with the appropriate tools!
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
Secure system from unintentional activation.
Following assembly, ensure a controlled restart.
english
7
5.2 Before installation
Installation position: Installation can be in any position.
Preferably: Actuator upright.
Prior to installation check pipelines for dirt and, if required, clean.
Dirt filter: To ensure that the solenoid valve
functions reliably, a dirt filter ( 400 µm) must
be installed in front of the valve inlet.
5.3 Installation
Sealing material must not get into the device.
Hold the device with a suitable tool (open-end wrench) on the
body and screw into the pipeline.
NOTE!
Caution risk of breakage!
• Do not use the coil as a lever arm.
Observe direction of flow:
The arrow on the body indicates the direction of flow (no function
in opposite flow direction).
5.4 Electrical installation
DANGER!
Risk of injury due to electrical shock!
Before reaching into the system, switch off the power supply and
secure to prevent reactivation!
Observe applicable accident prevention and safety regulations for
electrical equipment!
WARNING!
Danger of electrical shock if the protective conductor contact
between the coil and body is missing!
Always connect protective conductor.
Check electrical continuity between coil and body.
Risk of short-circuit or escape of media through leaking screw
joints.
Ensure seals are seated correctly!
Carefully screw together coil and device socket or valve and
pipelines!
Note the voltage and current type as specified on the label.
Maximum residual ripple for direct current 10 %.
english
Type 0290