Owner manual
0258 - 13
english
1 )
Pause time with change of rotation 0.4 s.
2 )
Increased wear with continuous operation of the motor.
3 )
limited gas seal
4 )
Impurities (e.g., fluff etc.) should be pre-filtered, otherwise the function of the valve could be impaired.
5 )
At 24 V DC smoothed. Pulsed drive increases the rotation time (see also
8)
)
6 )
dependent on pressure/load
7 )
Higher currents considerably reduce the service life!
8 )
Higher temperatures limit the max. power loss of the potentiometers.
9 )
min. pulse length (the min. pulse length increases at no-load/ at pressure/load):
for LC: approx. 100 ms / for Mod.: approx. 100 ms
NOTE LCLC
LCLC
LC: Max. number of operations (at nominal torque) = 100,000
under laboratory conditions, 20 °C and 1 s drive time in each
case over the complete adjustment range.
ModMod
ModMod
Mod: Max. number of operations = 400,000 under laboratory
conditions, 20 °C and 1 s drive time in each case over the
complete adjustment range.
Direction of rotation depending on polarity
Rotation time LC: approx. 4 ... 8 s at 24 V DC
6)
for 100%
5)
Mod: approx. 28 s at 24 V DC
Electrical connection LC: for AMP socket 967066-1
and AMP contact 962885-1
Mod: circular plug according to DIN 43651
(6-pole and earth)
Position feedback LC: 5 kΩ lin
Mod: Potentiometer 1 kΩ linear (optional 5 kΩ
linear and models in conducting plastic)
Protective resistance Rs = 6.8 kΩ
Resistance change ca. 55 ... 75 % (at 100 % rotation path)
of potentiometer
max. slider current Standard design:
≤≤
≤≤
≤4 mA
of potentiometer Conduction plastic design:
≤≤
≤≤
≤65 µA
7)
max. power in LC: 7.5 V (Potentiometer terminals 1 and 3)
potentiometer Mod: 10 V (Potentiometer terminals 4 and 6)
max. power in LC: 0.25 W / 40 °C
potentiometer
8)
Mod: 0.5 W / 40 °C
Rated operating 24 V DC
voltage
9
))
))
)
Voltage tolerance ±10 %
Power consumption LC: 4.8 W
Mod: 3 W
Electrical data