DATA SHEET Type 6013 Plunger valve 2/2 way direct-acting • Direct-acting and compact valve up to diameter of DN 6.0 • Vibration-proof, bolted coil system • Increased leak-tightness with welded plunger guide tube • Explosion proof versions • Energy-saving pulse versions Product variants described in the data sheet may differ from the product presentation and description. Can be combined with Type 1087 Timer Type description Type 2518 Cable Plug DIN EN 175301-803 Form A Type 2513 Cable plug acc.
Type 6013 Table of contents 1. General Technical Data 4 2. Product versions 5 2.1. 2.2. Analytical version....................................................................................................................................................................5 DVGW version.........................................................................................................................................................................5 3. Circuit functions 5 4. Approvals 6 5.
Type 6013 10.5. Ordering chart accessories...................................................................................................................................................20 Cable plug Type 2518, Form A according to DIN EN 175301 - 803 .....................................................................................20 Cable plug Type 2513, form A acc. to DIN EN 175301 - 803...............................................................................................
Type 6013 1. General Technical Data Product properties Dimensions Detailed information can be found in chapter “6. Dimensions” on page 9. Material Body Seal Thermal insulation class of solenoid Performance data Duty cycle/single valve with block assembly on manifold Circuit function Electrical data Operating voltage Standard version Analytical version Voltage tolerance Medium data Brass, stainless steel 1.
Type 6013 2. Product versions 2.1. Analytical version Solenoid valves for higher requirements This version is particularly suitable for switching from extremely pure gaseous medium. All medium-affected parts are submitted to additional purification processes, so that the medium is not contaminated under any circumstances. The tightness test takes place at the Helium leak detector from a min. of 10 - 4 mbar I/sec. Product properties Material Body Seal Brass, stainless steel 1.
Type 6013 4. Approvals ATEX and IECEx approval for coils with fixed cable outlet ATEX: EPS 18 ATEX 1232 X II 2G Ex mb IIC T4 Gb II 2D Ex mb IIIC T130 ºC Db 5. IECEx: IECEx EPS 18.0110X Ex mb IIC T4 Gb Ex mb IIIC T130 ºC Db Materials 5.1.
Type 6013 ATEX/IECEx cable version 1 No. Element 1 Locknut 2 3 4 5 12 6 11 7 10 8 9 Visit product website 2 3 Stopper Shading ring 4 5 6 7 Spring Magnetic core Armature guide tube Seal 8 Armature seal 9 Valve body 10 Sub-base 11 12 Cover Coil Material Steel, surface finish thick-film passivated (brass version) Stainless steel 1.4305 PTFE coated (stainless steel version) Stainless steel 1.4105 Cu (brass version) Ag (stainless steel version) Stainless steel 1.4310 Stainless steel 1.
Type 6013 ATEX/IECEx version with junction box 1 2 3 4 5 6 7 8 9 10 11 12 13 No. 1 2 Element Junction box Locknut 3 4 5 Stopper Coil Shading ring 6 7 8 9 10 Spring Magnetic core Armature guide tube Cover Sub-base 11 Seal 12 Armature seal 13 Valve body Visit product website Material Aluminium Steel, surface finish thick-film passivated (brass version) Stainless steel 1.4305 PTFE coated (stainless steel version) Stainless steel 1.
Type 6013 6. Dimensions 6.1. Standard version Note: Dimensions in mm Threaded version G1/8 + G1/4 12 10 27 18 C 5.4 14.6 45.2 9 15 G1/8 (4x) M4 8 G A 24 32 35 E SW14 B D Sub-base version Ø 6.3 Ø 3.2 F 8.7 24 G3/8 connection version SW27 37.5 G 20 30 D M4 5.3 C A C 7 B Port connection Threaded version Sub-base version Coil size 8 10 A [inch] G⅛ G¼ G⅜ – B [mm] 32 46 50 32 E [mm] 32 40 Visit product website C [mm] 20.8 26.8 39.8 14.3 D [mm] 32.6 49 38 32.
Type 6013 6.2. ATEX/IECEx cable version Note: Dimensions in mm Threaded version G3/8 Cable length acc. to order specification 5.4 C 45.2 G1/8 (4x) M4 8 G A 24 32 35 SW14 E B D F Sub-base version C 8.7 24 6.3 3.2 Threaded version G3/8 G 20 SW27 37.5 D B Port connection Threaded version Sub-base version Coil size 5 6 A [inch] G⅛ G¼ G⅜ – B [mm] 32 46 50 32 E [mm] 32 40 Visit product website M4 C [mm] 20.8 26.8 39.8 14.3 D [mm] 32.6 49 38 32.6 5.
Type 6013 6.3. ATEX/IECEx junction box version Note: Dimensions in mm Socket version G1/8 + G1/4 Cable gland included in the scope of delivery 68 M20x1.5 (4x) M4 C 5.4 45.2 105 G1/8 G 8 A B 24 D 32 E SW14 35 43.2 75.3 Port connection Threaded version Sub-base version Coil size 5 6 A [inch] G⅛ G¼ G⅜ – B [mm] 32 46 50 32 E [mm] 32 40 Visit product website F C [mm] 20.8 26.8 39.8 14.3 D [mm] 32.6 49 38 32.
Type 6013 6.4. Manifold mounting Single manifold Note: • Dimensions in mm • For detailed information on the installation of manifolds, see “Manifolds for block mounting” on page 14. 8 17 13 2.5 Ø 10.5 8 G1/8 24 32 M5 Ø 7.2 4.3 24 G1/8 32 Multiple manifold Note: Dimensions in mm A C 16 33 33 B Accessory part Quantity of valve places Total length B [mm] 65 Hole spacing C [mm] – Article no.
Type 6013 7. Performance specifications 7.1. Power consumption Circuit function A Orifice Port c onnection KV value Weight water Power consumption1.) [mm] 2.0 2.0 2.0 2.5 2.5 3.0 3.0 3.0 G⅛ G¼ Sub-base G⅛ G¼ G⅛ G¼ G⅜ [m3/h] 0.12 0.12 0.12 0.16 0.16 0.23 0.23 0.23 [g] 325 465 290 325 465 325 465 550 4.0 4.0 G¼ G⅜ 0.30 0.30 465 550 6.0 6.0 G¼ G⅜ 0.55 0.
Type 6013 8. Product installation 8.1.
Type 6013 Description Ex approvals Certification PTB 13 ATEX 1015 X, IECEx PTB 13.0034X Ex cable gland, Polyamide, 7…13 mm Dimensions Identification II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 TL L D SW E 36…45 mm 10 mm 20 mm 24 mm 28 mm 9.2. Special tool to turn the junction box Note: • This special tool is not supplied with the valve (see “10.5. Ordering chart accessories” on page 20). • This special tool can only be used with ATEX AC10 coils.
Type 6013 10.3. Ordering chart Standard version Note: Please note that the cable plug has to be ordered separately, see “10.5. Ordering chart accessories” on page 20 or separate datasheet Type 2518 . Circuit function Orifice Port c onnection [mm] KV value water1.) [m3/h] Coil power [W] With FKM seal, brass or stainless steel body (class B) 2.0 G⅛ 0.12 8 A, solenoid valve 2/2 way Direct-acting G¼ 0.12 8 Normally closed 2 (A) Sub-base (SFB) 1 (P) 2.5 G⅛ 3.0 G⅛ G¼ G⅜ G¼ 4.0 G⅜ G¼ 6.
Type 6013 Circuit function Orifice Port connection KV value Coil power Pressure water1.) range2.) [W] [bar] [mm] [m3/h] For high temperature applications (- 40 °C…+ 180 °C), PTFE seat seal, brass body (class H) 2.0 G¼ 0.12 8 0…12 A, solenoid valve 0…25 2/2 way 0…25 Direct-acting G¼ 0.23 10 0…6 Normally closed 3.0 2 (A) G⅜ 1 (P) 0.23 10 Voltage/ Frequency [V/Hz] Article no.
Type 6013 Analytical version Note: Please note that the cable plug has to be ordered separately, see “10.5. Ordering chart accessories” on page 20 or separate datasheet Type 2518 . Circuit function Orifice Port connection [mm] With FKM seal and brass body (class B) A, solenoid valve 2/2 way Direct-acting Normally closed 2.0 2.5 2 (A) 3.0 1 (P) 4.0 G⅛ G⅛ G¼ G¼ With FKM seal and stainless steel body (class B) A, solenoid valve 2.0 G⅛ 2/2 way Direct-acting 2.0 G¼ Normally closed 2 (A) 3.
Type 6013 10.4. Ordering chart ATEX/IECEx version Cable versions Note: • The maximum fluid temperature must not in any case exceed the permissible temperature class (T4 135 °C, 100 °C T5, T6 85 °C), minus 5 K). • With 3 m cable as standard. Other lengths on request. Circuit function Orifice Port c onnection [mm] KV value water1.) [m3/h] Coil power [W] Pressure range2.) [bar] Ex m T4 approved, with FKM seal and molded cable (3 m), single mounting only 2.0 Sub-base 0.
Type 6013 Circuit function Orifice Port c onnection [mm] A, solenoid valve 2/2 way Direct-acting Normally closed 2 (A) 1 (P) 3 G⅛ KV value water1.) [m3/h] 0.23 Coil power [W] Pressure range2.) [bar] Voltage/ Frequency [V/Hz] 9 0…5 24/UC 230/UC 24/UC G¼ Article no. Brass body 364540 x x Stainless steel body x x 351906 230/UC x 364541 4 0.3 0…1.2 24/UC 364544 230/UC 351941 x 364548 6 0.55 0…0.
Type 6013 Cable glands for ATEX/IECEx terminal box Note: • A polyamide cable gland version is included in the delivery. A nickel-plated brass version can be ordered at surcharge. • For more information on Ex cable glands see “6.1. Cable glands for ATEX/IECEx terminal box” on page 12. • For further information on the special key see “9.2. Special tool to turn the junction box” on page 15. Description Ex cable gland, brass, nickel-plated, 6…13 mm1.) Article no. 773278 Ex cable gland, polyamide, 7…13 mm1.
Bürkert – Close to You For up-to-date addresses please visit us at www.burkert.com Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom Russia China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan Canada USA United Arab Brazil Uruguay Emirates South Africa Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co.