User's Guide

75.1046 V3 July 2005 [Rev. 7/21/2005] Page 6 of 6
SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION
The loop detector will not work.
The green LED is off.
There is no power supply to the
loop detector.
Check power supply.
The loop detector will not work.
The red LED is flashing slowly
(0.5 Hz).
The corresponding loop is
shorted.
Check the loop cable.
The loop detector will not work.
The red LED blinks at either 1Hz
or 2Hz.
The frequency of oscillation falls
outside the allowed range.
Adjust frequency with dip
switches
or change loop turns.
The loop LED is detecting properly
but the contact is not made.
Bad connection of the relay
contacts.
Check relay connections.
Dip switches 5 to 8 are not
responding properly.
Their function varies according to
dip switch #10 setting.
Check the appropriate loop
mode required and adjust
dip switch #10.
If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call B.E.A., Inc.
for further assistance during Eastern Standard Time at 1-800-523-2462 from 8am - 5pm.
For after-hours, call East Coast: 1-866-836-1863 / Mid-West: 1-888-308-8843
West Coast: 1-888-419-2564. DO NOT leave any problem unresolved. If you must wait for the following workday to call
B.E.A., leave the door inoperable until satisfactory repairs can be made.
NEVER sacrifice the safe operation of the automatic door or gate for an incomplete solution.
Web: www.beasensors.com
TROUBLE -
SHOOTING
COMPANY
CONTACT