User's Guide
75.1046 V3 July 2005 [Rev. 7/21/2005] Page 3 of 6
WARNING : Do not remove the grease on the connector's pins.
Pin 1 : Power Supply
Pin 2 : Power Supply
Pin 3 : Relay 2 (NO)
Pin 4 : Relay 2 (COM)
Pin 5 : Relay 1 (NO)
Pin 6 : Relay 1 (COM)
Pin 7 : Loop A
Pin 8 : Loop common and connect to ground
Pin 9 : Loop B
Pin 10 : Relay 1 (NC)
Pin 11 : Relay 2 (NC)
I. THE 3 CONFIGURATIONS
• Configuration A : single loop detector (MATRIX-S) ;
• Configuration B : dual loop detector in independent mode (MATRIX-D with dip switch #10 OFF) ;
• Configuration C : dual loop detector in combined mode (MATRIX-D with dip switch #10 ON).
II. POTENTIOMETERS
• A potentiometer for adjustment of the maximum duration of a presence
detection : from 1 min to infinity ; (see Fig. 1)
• A potentiometer for adjustment of the linear sensitivity (∆f) for the loop A :
from 0.005% to 0.5 % ; (see Fig. 2)
• A potentiometer for adjustment of the linear sensitivity (∆f) for the loop B :
from 0.005% to 0.5 %. (see Fig. 2)
Configuration A
Single loop
Configuration B
Dual loop in independent mode
Configuration C
Dual loop in combined mode
Dip Switch
OFF ON OFF ON OFF ON
DS#1
High (loop A) Low (loop A)
[High –30%]
High (loop A) Low (loop A)
[High –30%]
DS#2
See next table
High (loop B) Low (loop B)
[High –30%]
High (loop B) Low (loop B)
[High –30%]
DS#3
Active mode Passive mode Active mode Passive mode Active mode Passive mode
DS#4
ASB OFF ASB ON ASB OFF ASB ON ASB OFF ASB ON
DS#5
Relay A :
Presence on
loop A
Relay A :
Pulse on loop
Relay A :
Presence on loop A
Relay A :
Pulse on loop A
Not used Not used
DS#6
Relay A :
Pulse on loop
A
entry
Relay A :
Pulse on loop A
exit
Relay A :
Pulse on loop A
entry
Relay A :
Pulse on loop A
Exit
Relay B :
Non-Directional
mode
Relay B:
Directional A→B
mode
DS#7
Relay B :
Presence on
loop A
Relay B :
Pulse on loop A
Relay B :
Presence on loop B
Relay B :
Pulse on loop B
Relay B :
Pulse on loop B
Relay B :
Pulse on loop A
DS#8
Relay B :
Pulse on loop
A
entry
Relay B :
Pulse on loop A
exit
Relay B :
Pulse on loop B
entry
Relay B :
Pulse on loop B
exit
Relay B :
Pulse on loop entry
Relay B :
Pulse on loop exit
DS#9
100 ms 500 ms 100 ms 500 ms 100 ms 500 ms
DS#10
Not used Not used Independent Combined mode Independent Combined mode
WIRING
PROGRAMMING
M
i
n
M
a
x
1
m
i
n
1
0
m
i
n
1
H
2
H
5
H
2
0
H
I
n
f
i
n
i
t
y
P
r
e
s
e
n
c
e
t
i
m
e
M
i
n
M
a
x
0
.
5
%
0
.
4
4
%
0
.
3
4
%
0
.
2
5
%
0
.
1
8
%
0
.
1
%
0
.
0
0
5
%
S
e
n
s
i
t
i
v
i
t
y
FIG. 2
FIG. 1
WARNING:
Pin #8 must be connected to the loop and to ground
!