REPAIR PARTS
# PART DESCRIPTION
1 410036 Top handle
2 410040 Top screws
3 410033 Capacitor
4 410034 O-Ring
5 410039 Bottom plate
6 410030 Snap ring impeller
7 410038 Oil seal
8 410025 Pump body
9 410043 Impeller bolt
10 410026 Impeller
11 410037 Washer impeller
12 410031 Mechanical seal
# PART DESCRIPTION
13 350335 Lower bearing
14 410028 Stator
15 410032 Motor housing
16 410027 Shaft / Rotor
13 410029 Upper bearing
17 410045 Capacitor housing
18 410035 Power cord
19 450453 Mechanical switch
20 450447 Vertical switch
21 450402 Screws (4)
22 350132 Switch bracket
Repair parts may be ordered from your authorized point of sale or from
BUR-CAM PUMPS
400500E
STEP 3
Cement 2” adaptor to
pipe
STEP 2
Install sewage basin
STEP 4
Drill a 1/4” hole
SEWAGE PUMP APPLICATION
STEP 5
Install discharge
pipe and lower
pump in centre of
basin
STEP 6
Set gaz tight
cover, discharge
and vent pipes
STEP 7
Install check
valve
STEP 8
Connect to receptacle
STEP 9
Fill with water and
test operation
STEP 10
Secure cover and
make vent connection
18
17
16
13
15
14
13
12
11
1
2
3
4
7
5
6
8 9 10
19
22
21
20