Installation Instructions

REPAIR PARTS
REF. PARTS DESCRIPTION
1 310141 Ejector
2 310140.1 Valve and oat
3 310147.1 Suction pipe
4 750753P 1 1/4’’ foot valve
Repair parts may be ordered from your authorized point of sale or from BUR-CAM PUMPS
TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE
POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE
THE POWER FROM THE RECEPTACLE.
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where you’ve
purchased the pump, please contact us at 514 337-4415, and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.
TROUBLE PROBABLE CAUSE ACTION
Municipal water supply closed.
Automatic valve closed.
Float do not rise with water level.
Suction or ejector clogged.
Water level below suction in sump.
Improper function or missing check
valve in primary pump discharge.
Discharge line clogged.
Pumping height more than 15 ft.
Municipal water pressure under 20 PSI.
Municipal water supply partially opened.
Automatic valve partially opened.
Suction or ejector partially clogged.
Leaky primary pump check valve.
Discharge line partially clogged.
Automatic valve does not shut off.
Float is obstructed.
Turn on ball valve.
Check manually the valve operation.
Check for obstruction of oat action.
Clean.
Adjust the oat rod to shut off pump
prior to low water level.
Install a check valve below the ‘‘Y’’ tting
on your primary pump discharge base.
Check all pipes.
Reduce top lift to less than 15 ft. head.
Run a 3/4’’ direct line from municipal
water supply to reduce friction loss in pipe.
Turn on ball valve.
Check manually the valve operation.
Clean.
Replace.
Check all pipes.
Check manually the valve operation.
Check for obstruction or adjust rubber
grommet to proper off and on position.
No water is
drawn out.
Pump does not
pump water to
full capacity.
Pump does not
shut off.
4
3
21