STEP 2 Remove electrical power of your existing conventional primary sump pump
and verify that this primary sump pump is equipped with a check valve at the
pump discharge. If not, add a check valve before continuing your installation.
The sump pump check valve should be located at the primary pump discharge
and installed below the ‘‘Y’ tting.
STEP 3 Locate your CONTRACTOR SUMP BUDDY in an ideal position and cut the
existing discharge line to install the ‘‘Y’’ tting. The distance between the top of
the basin (oor) and the bottom of the valve have to be between 2’’ to 3’’.
STEP 4 Cut the desired length of pipe to connect the discharge line from the
CONTRACTOR SUMP BUDDY to the or ‘‘Y’tting. Run this discharge line with
ttings to adjust your CONTRACTOR SUMP BUDDY in vertical position.
STEP 5 This emergency back-up system is equipped with a built-in check-valve (A).
Some local rules may required a second check valve to be located on the water
supply line. Check with your local plumbing codes.
STEP 6 Close municipal water supply. Run a supply line (not less than 1/2’’, 3/4’
recommended) to the ideal position for an easy operation of the automatic
control valve of the CONTRACTOR SUMP BUDDY. Install a ball valve (B) near
the pump area, to close
water supply for servicing
at a later date. Install a
vertical pipe with a cap
on the end to prevent
water hammering (C).
STEP 7 Flush this new line, before
next step, to remove
any debris which may
obstruct the water flow
in your CONTRACTOR
SUMP BUDDY.
STEP 8 Screw the automatic
control valve to the supply
line using an union to
allow servicing at a later
date (D).
STEP 9 Using the rubber rings (E),
adjust the oat to turn the
valve on at the proper
level. The oat should be
set to activate the valve
at least 2’’ higher than
the conventional electrical
pump setting, so that the
back-up pump will not
start prior to the main
electrical pump.
Check valve
required as
per step 2.
E
Float level
rubber ring
C
Water hammer
preventer pipe
B
Ball valve to
allow servicing
A
24’’
(61cm)
3/4’’
(2cm)
D
Union to
allow servicing