PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
CALIBRATE FLOW
This function allows the operator to enter the actual
flow rate of the sprayhead and the dilution by dispens-
ing both separately for one minute. The volumes are
then entered in milliliters per minute. (MI/M)
Procedures to calibrate the sprayhead flow rate:
1. Place a container, accurately graduated in milliliters,
and with a minimum capacity of 1800 milliliters,
beneath the funnel on the brewer.
2. Press and hold the ® pad until the display reads
WARMER OFF. Release the ® pad. Press and re-
lease the ® pad until the display reads CALIBRATE
FLOW.
3. Press and release YES to advance to the SPRAY-
HEAD CAL? function screen. (Pressing NO in the
CALIBRATE FLOW screen will advance to the next
function screen, BREW COUNTERS).
4. Press and release the YES pad. The display should
read CONTAINER READY? If the container is under
the funnel, press YES. The display should read
CALIBRATE SPRAY .. PRESS BREW TO START.
5. Press and release the "BREW" pad. The display
should read CALIBRATE SPRAY .. 60 SEC TO
FINISH. The 60 second timer on the display will
count down to zero. When the counter reaches
zero, the display will change to ENTER MI., along
with a number measured in ounces per minute.
6. Measure the amount of water in the container and
using the (-) or (+) pads, adjust the amount on
the display to match the amount in the container.
Then press DONE.
7. The display should now read NEW SPRAY FLOW,
along with the correct flow rate of the sprayhead
in ounces per minute. After about 5 seconds,
the display will return to the CALIBRATE FLOW
screen.
8. To exit the CALIBRATE FLOW program, press NO to
advance to the next function screen, or press the
"ON/OFF/LOWER" pad located on the front switch
panel to exit the CALIBRATE FLOW function and
return to the MAIN SCREEN.