LCA-2 LCC-2 ® BUNN WER PO Y AD RE N IO RT PO NSE RI LL FI RE OP! ST T HO G NIN AR ! W IDS IQU TL HO ! ES UID LIQ NT ME SE TIS ER AV ER WAT DS AU CH INSTALLATION & OPERATING MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 34766.0000 12/02 ©2002 Bunn-O-Matic Corporation www.bunnomatic.
CONTENTS Warranty ..................................................................................................................................... 2 Introduction ................................................................................................................................ 3 User Notices ............................................................................................................................... 3 Electrical Requirements ...............................................
INTRODUCTION The Liquid Coffee Ambient Dispenser (LCA-2) and the Liquid Coffee Chilled Dispenser (LCC-2) delivers two types of coffee plus hot water. The dispenser can be set up for continuous draw (by the cup) for self-serve applications, or portion-control to fill carafes and decanters for wait staff. Product Flavor Profile is extended with chilled product storage cabinet featured in the LCC-2. USER NOTICES Carefully read and follow all notices on the equipment and in this manual.
ELECTRICAL REQUIREMENTS CAUTION: The dispenser must remain disconnected from the power source until specified in Electrical Hook-Up. The LCA-2 and LCC-2 dispensers are supplied with a 120-volt / 15 Amp cord set and require a 2-wire, grounded, individual branch circuit rated for 120 volts AC, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R.
INITIAL SET-UP NOTE: The LCC-2 (Chilled Unit) weighs approximately 80 lbs. (36.3 kg) and the LCA-2 (Ambient Unit) weighs approximately 70 lbs. (31.8 kg). If necessary, use more than one person when lifting or moving the dispenser. 1. 2. 3. 4. 5. 6. Locate and remove the information packets and tube kits from top of packaging and set aside. Remove foam packing and cut around the bottom of box. Remove the box and the rest of the foam packing.
SETTING DISPENSER FLOW RATE The dispenser comes from the factory with flow restrictors in the mix chambers. With the restrictors in place the dispense rate is about 1.8 oz./sec (53.2 ml/sec) and is used primarily for cup at a time dispensing. The flow restrictors can be removed to increase the dispense rate to about 2.5 oz./sec (74 ml/sec) for larger volume dispensing (airpots, carafes, etc.). Removing the restrictors: 1. Disconnect the dispenser from the AC power source. 2. Open the Product Cabinet door.
SELECTING THE CORRECT PUMP TUBING There are two pump tube sizes available for use with this dispenser. To determine the correct tubing for you application, first determine the dispenser flow rate you intend to use, refer to Setting Dispenser Flow Rate. Then look up the recommended tube size for the mix ratio of your concentrate, refer to the Tube Selection Chart. TUBE SELECTION CHART Dispense Rate 1.8 Oz/sec. (53 ml/sec.) 2.5 Oz/sec. (74 ml/sec.) Concentrate Ratios 25 30 35 40 3/16" I.D.
OPERATING CONTROLS AND INTERFACE 1. 2. 3. 4. 5. Dispense Handles: Pull and Hold to dispense product. Stop Switch: Momentary switch stops all dispense functions. Hot Water Switch: Push and Hold switch to dispense hot water from the center dispense tip. Portion Control Switch: Momentarily pushed by user to activate Portion Control Mode Function Selector Switch: Allows the user to set the dispenser into different dispensing modes. a. Rinse: Dispenses hot water only- Flushes the mix chamber and dispense tip.
INITIAL FILL & HEAT 1. Select Normal on the Function Selector Switch and Run on the Mode Selector Switch. 2. Confirm the water supply is on. 3. Connect the dispenser to the power source. The Red POWER LED will illuminate and water will begin flowing into the tank. The dispenser will automatically stop filling when the tank is full. The dispenser will not begin heating the water until after the tank is filled. Dispenser models with product chillers will begin to cool the cabinet at this time. 4.
FlavorGard™ Feature FlavorGard™ is a patented feed back control loop that monitors the mixed product and adjusts the concentrate delivery rate to maintain a consistent mix profile, i.e. Flavor Profile. The system consists of a conductance probe mounted in the final stages of the mixing chamber, a metering pump with RPM sensor and a digital controller.
Rinse Alarm Feature Periodic rinsing of the mix chambers and dispense tips is essential for proper maintenance and optimum performance of the dispenser. The automated Rinse Alarm feature has three levels of operation, Disabled, Warning Only and Warning with Brew Lockout, see chart for details. Alarm Level Selected Disabled Warning Only Alarm Mode None Rinse LED will come on 4 hrs prior to the selected time interval and remain on until the Rinse procedure has been performed.
PROGRAMMING THE DISPENSER Remove the lower splash guard assembly to access the digital programming module with LCD display. Press the Down Arrow key to inter the programming menu. Use the Up and Down Arrow keys to scroll through the menu screens. Select Exit to leave the programming function and return to normal operations. NOTE 1: Flashing menu items indicate which selection is active. NOTE 2: Values shown below are the factory default values for English units. NOTE 3: Values in [X - X] are the Min.
MENU SCREEN ACTION DESCRIPTION LOCK FLAVOR ? EXIT YES Select (YES) or (EXIT) Select YES, to Lock In sensor calibration. NOTE: Display will return to “Find LF Target” if sensor calibration is out of range. FLAVORS LOCKED EXIT NONE Confirms that sensor calibration was in range and accepted. Scroll down to continue. LF DISP VOLUME (-) 0.0oz (+) Use the (+) or (-) buttons to Set the volume to be dispensed during a Left Portion controlled dispense to: [0 - 256 Oz.
MENU SCREEN SET PASSWORD ? (-) 0 (+) ACTION DESCRIPTION Use the (+) or (-) buttons to Enter your own Code to prevent access to the remaining functions. [0 to 9999] change the password. Select the preferred units Used to select the preferred units of measurement. (Oz.
MENU SCREEN CAL LF WTR VOL (-) 36.0OZ (+) ACTION DESCRIPTION Use the (+) or (-) buttons to Enter the volume of the water measured from the enter volume collected Left dispenser in Oz. (mL). CAL LEFT SIDE ? EXIT YES NONE CAL RIGHT SIDE ? EXIT YES Select (YES) to enable Calibration routine. Scroll down to bypass this screen. Selecting Yes will enable the Right Dispenser Calibration routine, (see Pump Calibration).
MENU SCREEN ACTION DESCRIPTION BIB EMPTY -> 400 (-) EXIT (+) Use the (+) or (-) buttons to Used to set the Conductance Threshold for the adjust empty BIB threshold Empty BIB warning. 0 REFILL -> 155 (-) EXIT (+) Use the (+) or (-) buttons to Used to set the Conductance Threshold for the adjust Refill threshold Tank Refill Probe. WTR START DELAY (-) .15SEC (+) Use the (+) or (-) buttons to Dispense Valve ON Delay. Eliminates weak mix at adjust delay time the beginning of a dispense.
LOADING THE CONCENTRATE 1. Thoroughly mix concentrate by vigorously shaking the product Bag-In-Box (BIB). 2. Pull the BIB connector through the hole provided in the box and place it on the drip tray with the connector facing up. (See Fig. 1) 3. Open the dispenser door and locate the appropriate left or right BIB Adapter fitting. 4. Pull the Adapter fitting down and connect it to the BIB. (See Fig. 2) 5. Place the BIB upright in the machine, rotating it into position with the connector facing forward. 6.
OPERATING THE DISPENSER Set the Function Selector Switch to Normal and the Mode Selector Switch to Run. 1. Pull and Hold Dispense Mode (Cup at a time) a. Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up and place the container on top of the drip tray. b. Pull and Hold the corresponding dispense handle until the cup or other container is full. c. Remove cup or container. 2.
CLEANING & PREVENTATIVE MAINTENANCE General Cleaning and Sanitizing Procedures Note: The BUNN® Liquid Coffee Dispenser incorporates a “user selectable” rinse reminder feature, which lights the Rinse LED on the front panel and disables dispensing when it is time to rinse. See Programming Functions to activate this feature. Daily: RINSING 1. Open the dispenser door. 2. Select Rinse on the Function Selector Switch and Run on the Mode Selector Switch. 3. Close the dispenser door. 4.
REPLACING THE PUMP TUBING The pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a wear item and must be replaced periodically. How long the tubes last is dependent on usage and properties of the concentrate. Excessive wear will reduce the output of the pumps resulting in a weak mixed beverage. Bunn-O-Matic recommends replacing the Pump Tubing a minimum of once every 6 months or sooner if warranted.
DRAINING THE HOT WATER TANK CAUTION: The dispenser must be disconnected from the power source throughout these steps. 1. Disconnect the dispenser from the power source. 2. Shut off and disconnect the incoming water supply. 3. Remove the front splash panel. 4. Pull out drain tube to empty into a sink or a container with a minimum of five-gallon capacity. 5. Make sure drain clamp is closed. Then, remove drain plug. 6. Direct tube into sink or container and open drain clamp.
Troubleshooting A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Only qualified service personnel should perform inspection, testing, and repair of electrical equipment. • This dispenser is heated at all times. Keep away from combustibles.
Troubleshooting (Continued) Dispenser Diagnostics Screen Displayed Possible Cause Troubleshooting Procedures 1. Refill valve stuck open Service Required 2. Faulty refill probe Service Required 3. Faulty overflow switch Service Required 1. Tank Heater failure Service Required 2. Triac failure Service Required CHECK HEATING CIRCUIT 3. Tank Temp. sensor failure Service Required FILL TIME TOO LONG 1. Water shut off to dispenser Check water supply shut-off CHECK WATER SUPPLY 2.
Troubleshooting (Continued) Screen Displayed FINS TEMP SENSOR OUT OF RANGE Possible Cause Troubleshooting Procedures 1. Corresponding Temperature Sensor Probe wire(s) broken or disconnected. Service Required 1. Corresponding Temperature Sensor Probe wire(s) shorted to housing, or to each other. Service Required 1. Corresponding Temperature Sensor Probe wire(s) shorted to housing, or to each other. Check to confirm that wire(s) are not pinched between two surfaces or connected to each other. 1.
Field Calibration of the Concentrate Pumps / Dispenser Flow Rates The factory set Default Values for the Pump & Dispenser Flow Rates are very accurate and typically do not need to be field calibrated. However, if the mix ratio accuracy is ever in question, this procedure can be used to recalibrate the unit in the field. Equipment Required: 50 to 100 ml graduated cylinder, with 1 ml graduations. 64 Oz (2000 ml) graduated container.
Field Calibration of the Concentrate Pumps / Dispenser Flow Rates (Continued) Dispenser Flow Rate Calibration 13. Press Down Arrow Key to display the CAL LF WTR FLO menu screen. 14. Place a 64 Oz (2000 ml) graduated container under Left Dispense Tip and Pull the Left Dispense Handle momentarily. The dispenser will dispense water for 20 seconds and then shut OFF automatically. 15. Keep the graduated container under dispense tip until all the water stops dripping. 16.
SCHEMATIC WIRING DIAGRAM LCA-2, LCA-2C,LCC-2,LCC-2C L1 GRN LIMIT THERMOSTAT BLK SW.
SCHEMATIC WIRING DIAGRAM LCC-2A/LCA-2A L1 N GRN RFI SUPPRESION CAPACITOR BLK BLK DOUBLE POLE LIMIT THERMOSTAT 1 2 BLK-14 SW.