Specifications
Bunn-O-Matic Corporation
23
Test Switches
Press any of the input buttons on the membrane switch, the display will show which button is being pressed.
Test Frequency
The funnel sensing circuit is tuned to 125 kHz. If the circuit is not tuned correctly, then the funnel information will not
betransferredtothebrewer.Therefore,themicroprocessorisconstantlynetuningtogetascloseaspossibleto
125 kHz. It has eight possible tuning steps numbered 0 - 7. When you look at the “TEST FREQUENCY” screen you
see something like (124.7 KHZ .5) The 124.7 is the frequency, and the 5 is the tuning step. The decimal point next to
the 5 indicates the funnel is being detected; if the funnel is removed the decimal point should turn off.
Service Fault Messages
The brewer features several error messages for problems occurring within the machine. These error messages will
show up on the display.
This message will be shown if the control board does not see the programmed water
temperature with 60 minutes.
Thismessagewillbeshownifthecontrolboarddoesnotseethetankllwithin30min-
utes.
This message will be shown if the control board looses contact with the temperature
sensor or senses a short in the connection.
TEST SWITCHES?
NO YES
TEST FREQUENCY?
NO YES
HEATING TIME
TOO LONG
FILL TIME TOO
LONG
TEMP SENSOR
OUT OF RANGE
ENABLE
ON / OFF
ENABLE
ON / OFF
BREWBREW
®
READY TO BREW
WATER TEMP: 200°