ELECTRICAL REQUIREMENTS
Refer to the Data Plate on the dispenser, and local/national electrical codes to determine circuit requirements.
WARNING - If the power cord is ever damaged, it must be replaced by the manufacturer or its service agent with a special
cord available from the manufacturer or its service agent in order to avoid a hazard.
The LCA-1 is supplied with a 120-volt / 15 Amp cord set and require a 2-wire, grounded, individual branch circuit rated for
120 volts AC, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R.
The LCA-1A dispenser is internally wired from the factory for 220-240 volts AC, Single Phase, 50/60 Hz. It requires a 2-wire,
grounded, individual branch circuit rated for 240 volts AC
.
PLUMBING REQUIREMENTS
The dispenser may be connected to a cold or hot water system (140°F (60°C) Max.) with operating pressure between 20
and 90 psi (0.138 and 0.620 MPa) from a 3/8” (10mm) or larger supply line. A shut-off valve should be installed in the
line before the dispenser. Install a regulator in the line when pressure is greater than 90 psi (0.620 MPa) to reduce it to 50
psi (0.345 MPa). The water inlet fitting is 1/4” flare. The dispensers set up to deliver to 1.25 Oz./sec. (37.0 ml/sec.) and
require a water supply source that can deliver a minimum of 1.0 gpm (3.8 lpm) at the inlet fitting.
NOTE: Bunn-O-Matic recommends 1/4” tubing from the 3/8” water supply line. At least 18 inches (0.5m) of FDA approved
flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement
to clean the counter top. Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser. The size
and shape of the hole made in the supply line by this type of device may restrict water flow.
INTRODUCTION
The BUNN LCA-1 dispenser is design to hold up to 1/2 gal (2 l) of ambient - shelf stable liquid coffee con-
centrate. The dispenser is designed to operate when ambient temperatures are from 32°F (0°C) minimum to
95°F (35°C) maximum. Always follow the Concentrate Manufacturer’s Storage and Shelf Life recommendations.
BUNN recommends the use of our Easy Clear
®
Water Quality Systems to assure perfect taste.
Filter Kits - Easy Clear EQHP-10L w/Scale Inhibitor (Bunn-O-Matic part no. 39000.0001)
or
Easy Clear EQHP-10 (Bunn-O-Matic part no. 39000.0004)
USER NOTICES
Carefully read and follow all notices on the equipment and in this manual. They were written for your protec-
tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels.
00656.0001
00986.0002
37280.0001
37881.0000
As directed in the International Plumbing Code of the
International Code Council and the Food Code
Manual of the Food and Drug Administration (FDA),
this equipment must be installed with adequate
backflow prevention to comply with federal, state
and local codes. For models installed outside the
U.S.A., you must comply with the applicable Plumb-
ing /Sanitation Code for your area.
Artwork for P/N: 00656.0001
Artwork Rev: A
Drawn: REF
Date: 04/22/10
As directed in the International Plumbing Code of the International Code Council and the Food Code
Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate
backflow prevention to comply with federal, state and local codes. For models installed outside the
U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area.
NOTE - Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and
maintained in accordance with federal, state and local codes.
00824.0002
44806.1 072914 44806.1 072914
CE REQUIREMENTS
• This appliance must be installed in locations where it can be overseen by trained personnel.
• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.
• Appliance shall not be tilted more than 10° for safe operation.
• An electrician must provide electrical service as specified in conformance with all local and national codes.
• This appliance must not be cleaned by water jet.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabili-
ties, or lack of experience and knowledge, unless they have been given instructions concerning use of this appliance by
a person responsible for its safety.
• Children should be supervised to ensure they do not play with the appliance.
• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with a special
cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.
• Machine must not be immersed for cleaning.
• A weighted sound pressure level is below 70dB.
• Access to service area to be restricted to persons having knowledge and practical experience of the appliance in particular
as far as hygiene are concerned.
WARNING HOT LIQUIDS
RELEASED FOR PRODUCTIONDIR Num: 44806.0001 08, October 2014