Service & Repair Manual
Page 28
WARMER ELEMENT(S)
Location:
The warmer element(s) is located under the warmer
plate.
Test Procedures:
1. Disconnect the brewer from the power source.
2. With a voltmeter, check voltage across the two
wires at the warmer element with the "ON/OFF"
switch in the "ON" position. Connect the brewer
to the power source. The indication must be 120
volts ac for two wire 120 volt models and three
wire 120/208 and 120/240 volt models, or 230
volts ac for two wire 230 volt models.
3. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to Wiring
Diagrams and check wiring harness.
FIG. 28-1 WARMER ELEMENTS
FIG. 28-3 WARMER ELEMENT TERMINALS
SERVICE (cont.)
4. Check the resistance across the two terminals on
the warmer element. NOTE: There should be no
resistance reading between the heater sheath and
either terminal. Refer to the following chart.
If resistance is to speciļ¬cation, reconnect the two
wires to the warmer element.
If resistance is not to speciļ¬cation, replace the warmer
element.
Removal and Replacement:
1. Remove the three #4-40 screws securing the
warmer assembly to the brewer.
2. Lift the warmer assembly from the brewer.
3. Disconnect the two wires from the warmer element
terminals.
4. Remove the two #8-32 nuts securing the warmer
element to the warmer plate.
5. Securely install new warmer element.
6. Reconnect the two wires to warmer element ter-
minals.
7. Securely install warmer assembly on the brewer.
WHI/RED to ON/OFF Switch (Center Warmer)
YEL to ON/OFF Switch (Left Front Warmer)
WHI/VIO to ON/OFF Switch (Left Rear Warmer)
BRN/BLk to ON/OFF Switch (Right Front Warmer)
VIO to ON/OFF Switch (Right Rear Warmer)
WHI to Terminal Block (120V or
120/240V Brewers)
RED to Terminal Block (200V or
240V Brewers
100W-120V 132 - 152
100W-220V 450 - 532
100W-200V 372 - 432
WARMER RESISTANCE
TERMINAL TO SHEATH - INFINITE (OPEN)
41711.1 052009
FIG. 28-2 WARMER ELEMENTS