Service manual
Page 9
TROUBLESHOOTING (cont.)
PROBLEM
Brew cycle will not start (cont.) (CT, 
CTF,  CWT,  CWTA,  CWTB,  CWTF, 
CWTFA,  CWTFB,  SINGLE  CW  & 
SINGLE CWF)
Water is not hot
PROBABLE CAUSE
REMEDY
3. ON/OFF Switch
4. Start Switch
5. Timer
6. Solenoid Valve
7.  Water strainer/flow control     
(.222 GPM)
1. Tank Heater Switch
2. Limit Thermostat
CAUTION  -  Do  not  eliminate  or 
bypass limit thermostat.  Use  BOM 
replacement part #29329.1000
3. Control Thermostat
4. Tank Heater
Refer to Service - ON/OFF Switch 
for testing. See page 17
Refer to Service - Start Switch for 
testing procedures. See page 20
Refer to Service - Timer for testing 
procedures. See page 24
Refer to Service - Solenoid Valve 
for testing procedures. See page 
19
(A) Direction of flow arrow must 
be pointing towards brewer.
(B) Remove the strainer/flow con-
trol  and  check  for  obstructions. 
Clear or replace.
Refer to Service - Tank Heater 
Switch  for testing procedures. 
See page 22
Refer to Service - Limit Thermo-
stat  for  testing  procedures.  See 
page 16
Refer  to  Service  -  Control  Ther-
mostat for  testing procedures. 
See page 15
Refer to Service - Tank Heater for 
testing procedures. See page 21
10841 020503










