Service manual
Page 26
4.  Attach all wires to the replacement timer board 
prior to installation to the component mounting 
bracket. Refer to FIG. 22 when reconnecting the 
wires.
5.  Install new circuit board with spacers (as required) 
to the component mounting bracket.
6.  Adjust the timer as described below.
Timer Setting (Digital):
NOTE: Prior to setting or modifying volumes, check 
that  the  brewer  is  connected  to  water  supply,  the 
tank is properly filled, and a funnel and server are in 
place.
NOTE:  All  volume  settings  must be  done  with  the 
sprayhead installed.
1.  Modifying brew volumes. To modify a brew vol-
ume, first check that the SET/LOCK switch is in the 
“SET” position on the circuit board.
  To  increase  a  brew  volume,  place  the  ON/OFF 
switch in the “ON” position, press and hold the START 
switch until three clicks are heard. Release the switch 
and press it again one or more times. (Failure to re-
lease the switch within two seconds after the third click 
causes the volume setting to be aborted and previous 
volume setting will remain in memory) Each time the 
switch is pressed, two seconds are added to the brew 
time period. Allow the brew cycle to finish in order to 
verify that the desired volume has been achieved.
  To decrease a brew volume, place the ON/OFF 
switch  in the “ON”  position,  press and release  the 
START switch once for every two-second interval to 
be removed from the total brew time period; then im-
mediately press and hold down the START switch until 
three clicks are heard. Release the switch. (Failure to 
release the switch within two seconds after the third 
click  causes  the  volume  setting  to  be  aborted  and 
previous volume setting will remain in memory). Al-
low the brew cycle to finish in order to verify that the 
desired volume has been achieved.
2.  Setting brew volumes.   To  set a brew  volume, 
first check that the SET/LOCK switch is in the “SET” 
position on the circuit board. Place the ON/OFF switch 
in the “ON” position. Models Single CW only, place the 
selector switch in the half position. Press and hold the 
START switch until three distinct clicks are heard and 
then release the switch. (Failure to release the switch 
within two seconds  after  the  third  click  causes  the 
volume  setting  to  be  aborted and  previous  volume 
setting will remain in memory.
View the level of  the liquid  being dispensed.  When 
approximately 50 ounces is reached, turn the ON/OFF 
switch to “OFF”. 
NOTE: Several ounces of water will continue to sy-
phon from  the  tank  after  turning  the switch “OFF”. 
The brewer remembers this volume and will continue 
to brew batches of this size until the volume setting 
procedure is repeated.
NOTE:  When  brewing  coffee, volume  will  decrease 
due to absorption by the coffee grounds.
3.  Setting programming  disable  feature. If  it  be-
comes necessary to prevent anyone from changing 
brew time once programmed, you can set the SET/
LOCK switch to the “LOCK” position. This will prevent 
any further programming until switch is once again 
put into the “SET” position.
BLU/BLK wire from TL5 to P1
WHI/GRN wire from TL4 to Solenoid
WHI/BLU wire from TL3 to Solenoid
WHI wire from TL2 to P2
BLK wire from TL1 to P3
FIG. 22 DIGITAL TIMER WIRING
P2037
SERVICE (cont.)
DIGITAL BREW TIMER (Late Models)(cont.) 
10841 020503