TROUBLESHOOTING (cont.)
PROBLEM
Weak beverage
Dry coffee grounds remain in 
the funnel
Brewer is making unusal noises 
(CT, CTF, CWT, CWTA, CWTB, 
CWTF, CWTFA, CWTFB, SINGLE 
CW & SINGLE CWF)
PROBABLE CAUSE
1. Filter Type
2. Coffee Grind
3. Sprayhead
4. Funnel Loading
5. Water Temperature
1. Funnel Loading
1. Solenoid
2. Plumbing Lines
3. Water Supply
REMEDY
BUNN®  paper filters must be used 
for proper extraction.
A fine or drip grind must be used 
for proper extraction.
A clean spray-head must be used 
for proper extraction.
The BUNN® paper filter must be 
centered in the funnel and the 
bed of  ground  leveled  by gentle 
shaking.
Place an empty funnel on an empty 
dispenser beneath the sprayhead. 
Initiate a brew cycle and check the 
water temperature immediately 
below the sprayhead with a ther-
mometer. The reading should not 
be less than 195°F (76°C). Adjust 
the control thermostat to increase 
the water temperature. Replace if 
necessary.
The BUNN® paper filter must be 
centered in the funnel and the 
bed of grounds leveled by gently 
shaking.
The  nut on the  solenoid must 
be  tight  or  it  will  vibrate  during 
operation.
Plumbing lines should not resting 
on the counter top.
(A) The brewer must be connected 
to a cold water line.
(B) Water pressure to the brewer 
must not exceed 90 psi (620 kPa). 
Install a regulator if necessary to 
lower the working pressure to ap-
proximately 50 psi (345 kPa).