Specifications

Page 34
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
Procedure to test switches:
The following switches can be individually tested:
SINGLE Brewers
Full Batch
Half Batch
Power
Brew Switch
Left Hidden
DUAL Brewers
<- <- Full Batch Full Batch -> ->
<- <- Half Batch Half Batch -> ->
<- <- Power Power -> ->
<- <- Brew Switch Brew Switch -> ->
Left Hidden DONE
(-) (+)
1. Press and hold the right hidden switch until the dis-
play reads SET LANGUAGE. Press the right hidden
switch until the display reads SERVICE TOOLS.
2. Press and release YES. The display should now read
TEST OUTPUTS? Press and release NO to advance
to TEST SWITCHES.
3. Press and release YES. The display should now
read RIGHT HIDDEN TO EXIT, and then NOTHING
PRESSED.
4. From this screen, press any of the switches on the
front of the brewer. While the switch is pressed, the
display shows the name of that switch. If the name
does not appear, or if it remains after the switch has
been released, the switch is defective. Each switch
can be tested in this manner.
After all switches have been tested, press and release
the right hidden switch to return to the TEST SWITCHES
screen. To exit programming, press and release the
ON/OFF switch (either for DUAL brewers) to return to
the MAIN SCREEN
TEST OUTPUTS?
NO YES
SERVICE TOOLS?
NO YES
TEST SWITCHES?
NO YES
RIGHT HIDDEN
TO EXIT
NOTHING PRESSED
PRESSING NO WILL
ADVANCE TO
FACTORY DEFAULTS
TEST SWITCHES
NO YES
PRESSING NO WILL
ADVANCE TO
TEST FREQUENCY
AFTER ALL SWITCHES ARE TESTED
PRESS RIGHT HIDDEN TO RETURN
TO TEST SWITCHES
FACTORY DEFAULTS
NO YES
41344 112508