PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
CALIBRATE FLOW (Continued)
Procedure to calibrate the bypass flow rate:
1. Place a container, accurately graduated and with a
minimum capacity of 60 ounces, beneath the fun-
nel.
2. Press and hold the right hidden switch until the
display reads SET LANGUAGE. Press the right
hidden switch until the display reads CALIBRATE
FLOW.
3. Press and release YES to advance to the SPRAY
HEAD CAL function screen. Press and release NO
to advance to BYPASS CAL.
4. Press and release the YES switch. The display
should read CONTAINER READY? If the container
is under the funnel, press YES.
5. The display should read CALIBRATE BYPASS. Press
and release the BREW switch (on the side to be
calibrated on DUAL brewers) to begin the flow for
calibration. The display should read CALIBRATE
BYPASS...60 SEC TO FINISH. The 60-second timer
on the display will count down to zero. When the
counter reaches zero, the display will changes to:
OZ/M, along with a number (SINGLE brewers)
LEFT or RIGHT OZ/M, along with a number (DUAL
brewers).
6. Measure the amount of water in the container and
using the (-) and (+) switches, adjust the amount
of the display to match the amount in the container.
Then press DONE.
7. The display should now read:
NEW BYPS FLOW (SINGLE brewers)
NEW L or NEW R BYPS FLOW (DUAL brewers)
along with the correct flow rate of the bypass. Af-
ter about 5 seconds, the display will return to the
CALIBRATE FLOW screen.
8. Repeat steps 1-7 to calibrate the other side for
DUAL brewers.
9. To exit the CALIBRATE FLOW function and advance
to the next function screen, press and release NO.
To exit programming, press and release the ON/
OFF switch (either for DUAL Brewers) to return to
the MAIN SCREEN.
SPRAYHEAD CAL
NO YES
CALIBRATE FLOW?
NO YES
BYPASS CAL?
QUIT YES
CONTAINER READY?
QUIT YES
CALIBRATE BYPASS
PRESS BREW START
CALIBRATE BYPASS
60 SEC TO FINISH
NEW L BYPS FLOW
XX.X OZM
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
LEFT OZ XX.X
(-) DONE (+)
NEW BYPS FLOW
XX.X OZM
OZ XX.X
(-) DONE (+)
SINGLE
BREWERS
DUAL
BREWERS
5 sec
CALIBRATE FLOW?
NO YES
5 sec
41344 112508