Specifications
Page 22
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
SPRAYHEAD CAL
NO YES
CALIBRATE FLOW?
NO YES
CONTAINER READY?
QUIT YES
CALIBRATE SPRAY
PRESS BREW START
CALIBRATE SPRAY
60 SEC TO FINISH
LEFT OZ XX.X
(-) DONE (+)
NEW L SPRY FLOW
XX.X OZM
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
5 sec
CALIBRATE FLOW
This function allows the operator to enter the actual flow
rate of the sprayhead and the bypass for each side of the
brewer by dispensing both separately for one minute.
The volumes are then entered into the brewer.
Procedure to calibrate the sprayhead flow rate:
1. Place a container, accurately graduated and with a
minimum capacity of 60 ounces, beneath the fun-
nel.
2. Press and hold the right hidden switch until the
display reads SET LANGUAGE. Press the right
hidden switch until the display reads CALIBRATE
FLOW.
3. Press and release YES to advance to the SPRAY
HEAD CAL function screen. (Pressing NO in the
CALIBRATE FLOW screen will advance to the next
function screen, BREW COUNTERS).
4. Press and release the YES pad. The display should
read CONTAINER READY? If the container is under
the funnel, press YES.
5. The display should read CALIBRATE SPRAY.
Press and release the BREW switch (on the side
to be calibrated for DUAL brewers) to begin the
sprayhead flow for calibration. The display should
read CALIBRATE SPRAY...60 SEC TO FINISH. The
60-second timer on the display will count down to
zero. When the counter reaches zero, the display
will change to:
OZ, along with a number (SINGLE brewers).
LEFT or RIGHT OZ, along with a number (DUAL
brewers).
6. Measure the amount of water in the container and
use the (-) and (+) switches to adjust the amount
of the display to match the amount in the container.
Then press DONE.
7. The display should now read:
NEW SPRY FLOW (SINGLE brewers)
NEW L or NEW R SPRY FLOW (DUAL brewers)
along with the correct flow rate of the sprayhead.
After about 5 seconds, the display will return to the
CALIBRATE FLOW screen.
8. Repeat steps 1-7 to calibrate the other side for
DUAL brewers.
9. To exit the CALIBRATE FLOW function and advance
OZ XX.X
(-) DONE (+)
NEW SPRY FLOW
XX.X OZM
CALIBRATE FLOW?
NO YES
5 sec
to the next function screen, press and release NO.
To exit programming, press and release the ON/
OFF switch (either for DUAL Brewers) to return to
the MAIN SCREEN.