Specifications
Page 11
READY TEMP
This function allows the operator to set the minimum
temperature allowable to start a brew cycle. The range
can be from 2° to 20° F within the set temperature.
The water must be at the READY temperature or higher
for the display to indicate READY TO BREW. If brew
lockout is enabled, the brewing process will not start
below this READY temperature.
Procedure to set ready temperature
Range: 2° to 20° F (2° to 10° C)
1. Press and hold the right hidden switch until display
reads SET LANGUAGE. Press and release the right
hidden switch until display reads READY TEMP:
XXX°.
2. Using (-) and (+), adjust the ready temperature.
3. When finished, press DONE to save the new setting
and to advance to the next function screen, BREW
SETTINGS ?. Press and release the ON/OFF switch
(either on DUAL brewers) to exit programming and
return to the MAIN SCREEN.
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
BREW SETTINGS ?
NO YES
READY TEMP: XXX°
(-) DONE (+)
41344 112508