My Café® AP PROGRAMMING MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 41170.
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor. 2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years.
CONTENTS LOCKOUT SWITCH..............................................................................................4 PROGRAMMING SWITCHES...............................................................................5 PROGRAMMING..................................................................................................6 Page 3 41170.
ADJUSTMENTS & PROGRAMMING PROGRAMMING THE BREWER The programming of the brewer is divided into two levels. Brewing adjustments are in Level 1. Service functions are accessed in Level 2. The following function screens are in order of appearance. Each screen will have instructions on how to access, and the procedures to program the various functions of the brewer. IMPORTANT PROGRAMMING NOTES - READ CAREFULLY To exit the programming mode at any time, press and hold "Hidden" switch located on the front panel.
PROGRAM FUNCTIONS MAIN SCREEN ER EW R DB PO to Au HIDDEN SWITCH Press until display reads "BREW LOCKOUT" Press/hold to exit program SMALL BREW Step backwards through screens BREW LOCKOUT: NEXT BREW LOCKOUT ? NO DONE YES Prevents brewing if the water temperature is less than the "SET READY" temperature. To access this function screen press and hold the hidden switch. Release when the display reads: "BREW LOCKOUT". The YES or NO should be flashing.
PROGRAM FUNCTIONS BREW LOCKOUT ? NO DONE BREW OZ A: (-) YES 8.0 DONE (+) BREW METER A: 2 - + BREW OZ B: (-) DONE 6.0 (+) BREW METER B: 1 - + ENTER SERVICE # NO DONE YES ENTER PASSWORD 0 0 0 SET PASSWORD 0 0 0 SET LANGUAGE ? NO YES UNITS METRIC DONE ENG SET TEMP: (-) 200° DONE (+) SET READY: 195° (-) DONE (+) HOT H2O LOCKOUT ? NO DONE YES BREW LOCKOUT (YES/NO) Setting to "YES" only allows brewing at or above the "SET READY" temp screen. BREW OZ.
PROGRAM FUNCTIONS H2O READY: 190° (-) DONE (+) ENTER ASSET # ? NO YES SetPulseBrew A ? NO DONE YES AIR TIME A: 20 (-) DONE (+) SetPulseBrew B ? NO DONE YES AIR TIME B: 20 (-) DONE (+) BREWS TO EMPTY (-) 25 (+) Enabl EnergySavr NO DONE YES BREW COUNT ## NO YES CALIBRATE FLOW ? NO YES FLOW COUNTS / 10 oz (-) 640 (+) NUMBER OF EJECTS SINGLE DOUBLE BREWS ON THIS SEAL RESET NEXT HOT H2o READY Sets the minimum temperature allowable to start dispensing hot water.
PROGRAM FUNCTIONS SERVICE TOOLS ? NO YES TEST OUTPUTS ? NO YES INDEX B DUMP NEXT MOTOR LOAD WaterInIet ON NEXT # OFF AIR PUMP ON NEXT OFF VENT VALVE ON NEXT OFF HotWaterAir PUMP ON NEXT OFF WATER PUMP ON NEXT OFF TANK HEATER RELAY ON NEXT OFF TANK HEATER TRIAC ON NEXT OFF TEST SWITCHES ? NO SERVICE TOOLS allows testing of load components and switches. It should only be used by trained technicians. TEST OUTPUTS allows testing of load components by manually turning them ON/OFF.
PROGRAM FUNCTIONS SET REFILL NO THRESHLD YES # REFILL (-) ### DONE (+) YES EXIT PROGRAM MODE TO MAIN SCREEN Model: Software version: AutoPOD BREWER VERSION REFILL Adjust sensitivity of refill probe according to water quality. Always make sure that the # on the right is larger than the # on the left when water is contacting the tank refill probe. FACTORY DEFAULTS Reset all brew settings, calibrations back to factory presets. Requires following "INITIAL SETUP" procedure.