Specification Sheet
BUNN® reserves the right to change specifications and product design without notice. Such revisions do not entitle
the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
For most current specifications and other info visit bunn.com.
Last Updated:
11/19/2019
ITCB-DV-DBC
Server(s) sold separately
Two programmable batch switches allow full and half batches of iced tea
Brews into all BUNN iced tea dispensers (except TDS-5),1.9 to 3.8L airpots,
thermal carafes and can accommodate BUNN ThermoFresh® Servers
Brew counter keeps track of how many batches brewed
BrewWISE® intelligence with pre-infusion and pulse brew for maximum flavor
extraction
Digital temperature control and cold brew lockout
Display advertising messages and machine status
Dual voltage adaptable (Can operate at 120V/15 amp or 120/208-240V/20 amp)
Easy pulse display allows for simplified programming of pulse routine
Energy-saver mode reduces tank temperature during idle periods
English and Spanish alphanumeric display
Large tank provides back-to-back brewing capacity and allows 3 or 5gal (11.4 to
18.9L) tea batches
Servers not included unless otherwise noted
Agency:
Specifications Additional Features
35700.0000Product #: Translucent Tea FunnelFunnel: Quickbrew Funnel Tip
PlumbedWater Access: UpperFaucet: Smart Funnel Compatible
Stainless
Finish:
With Overlays
Black PlasticFunnel: Quick Brew
Height: 34.4" Width: 23.8" Depth: 11.5"
(87.4cm) (60.5cm) (29.2cm)
Electrical & Capacity
Volts* Amps Watts
Cord
Attached
Plug Type
8oz cups/hr
236ml cups/hr
Input H²O
Temp.
Phase
# Wires
plus Ground
Hertz
120 14 1700 - - 78
60°F (15.5°C)
1 2 60
120/208
13 2650 -
N/A
136
60°F (15.5°C)
1 - -
120/240
15 3500 -
N/A
162
60°F (15.5°C)
1 - -
*When a BUNN is machine rated 120/208-240V, 120/208V or 120/240V, the higher voltage is the supply voltage needed to power the machine. The 120V is there to supply power to some components rated 120V in the machine, but it is not the supply voltage
and would not power the machine if the machine is marked with the before mentioned ratings.
Plumbing Requirements CAD Drawings
PSI kPa
Fitting Supplied
Water Flow Required (GPM)
20-90 138-621
1/4" Male Flare Fitting
-
2D
Revit
KLC
•