Service and Repair Manual

9
TROUBLESHOOTING (cont.)
PROBABLE CAUSE REMEDYPROBLEM
Product level in ULTRA is lower
than level Probe - ULTRA running;
Powder Auto-Fill door lamp flashes
two times
Product level in ULTRA is lower
than level Probe - ULTRA running;
Powder Auto-Fill door lamp flashes
three times
Product level in ULTRA is lower
than level Probe - ULTRA running;
Powder Auto-Fill door lamp flashes
four times
The ULTRA product tastes “watery”
or “sugary”
Powder Auto-Fill dispenses dry
product only - dry powder build-up
in mixing and whipper chambers
1. Powder Auto-Fill not pulled com-
pletely forward.
2. ULTRA level probe misaligned.
1. Powder Auto-Fill hopper not in-
stalled properly.
1. Refill time exceeded five min-
utes.
1. Improper adjustment of product
mix ratio.
1. Powder Auto-Fill not connected
to water source.
2. Water source turned off.
3. Water line obstructed.
1. Check that the Powder Auto-Fill
is pulled completely forward until
the guide rails roll into the indented
position.
2. Position the ULTRA level probe
so that it is located in the notch of
the ULTRA hopper and touching the
contact protruding from the front of
the PAF platform.
1. Properly position the Powder
Auto-Fill hopper.
.
Check that the SERVICE switch is
released or reset by opening and
closing the Powder Auto-Fill door.
Adjust the product mix ratio per
instructions in Powder Auto-Fill
Adjustment. See page 5.
1. Connect the Powder Auto-Fill to a
20 to 90 psi (138 to 620 kPa)water
source.
2. Turn water source on.
3. Remove obstruction.
41087.1 060112