Service and Repair Manual

7
FAULT LIST
Door Lamp Fault
ON Normal operation - Powder Auto-Fill ready to
dispense
Flashes ON/OFF at 50% duty cycle Low product level in Powder Auto-Fill hopper
Two flashes about every 2 seconds ULTRA/Powder Auto-Fill probe circuit open
Three flashes about every 2 seconds Powder Auto-Fill hopper not in place
Four flashes about every 2 seconds ULTRA refill exceeded 5 minutes
OFF Door not closed
41087.1 060112
REQUIRED REGULAR MAINTENANCE:
Semi Annual:
Bunn Kit #45319.0000 is required to perform the semi annual Preventive maintenance:
Note: Service caused by failure to perform required maintenance is not covered by warranty.
Kit Contents
Inventory this kit for completeness before proceeding.
Part Number Qty. Description
25736.0000 1 Dispense Tip
25734.0000 1 Whipping Chamber
24733.0001 1 Mixing Chamber
28866.0000 1 Receptacle
26356.0000 1 Shaft Seal
24733.0010 1 O-Ring
25902.0000 1 Frother
25903.0001 1 Ejector Elbow