Manual

15
Sensor Docking Station
Sensor Docking Station Installation
IMPORTANT: Physical installation of the Sensor Docking Station should
always begin with installing the pyrometer (and any other sensors).
This is because the pyrometer cable length is limited and will aect
the nal position of the sensor docking station. For more information
on installing the pyrometer, see pages 11-14.
1. Prepare the power harness.
a. Crimp a ring terminal on the black chassis ground wire.
b. Crimp a ring terminal on the white battery ground wire.
c. Crimp the spade on the red power wire.
2. Locate a key-on fuse.
a. It only has power when the key is in the “on” (or “run”)
position.
b. Use a 12 volt test light and/or your vehicle manual to
locate one.