Manual
15
Sensor Docking Station
Sensor Docking Station Installation
IMPORTANT: Physical installation of the Sensor Docking Station should
always begin with installing the pyrometer (and any other sensors).
This is because the pyrometer cable length is limited and will aect
the nal position of the sensor docking station. For more information
on installing the pyrometer, see pages 11-14.
1. Prepare the power harness.
a. Crimp a ring terminal on the black chassis ground wire.
b. Crimp a ring terminal on the white battery ground wire.
c. Crimp the spade on the red power wire.
2. Locate a key-on fuse.
a. It only has power when the key is in the “on” (or “run”)
position.
b. Use a 12 volt test light and/or your vehicle manual to
locate one.