FILTEr mAINTENANCE:
The intake system should be cleaned at least every three months; in dusty climates the lter should
be cleaned more often. Cleaning the intake is a two part process, the rst part of the process
involves the physical cleaning of the lter with soap and water and the second part involves
oiling the lter. To properly clean the lter a Bully Dog cleaning kit should be used. Cleaning kits
are available at any Bully Dog dealer.
PART 1, CLEANING THE FILTER:
1. Remove lter from lter housing. Clean the lter housing if
necessary.
2. Begin the cleaning process by ridding the lter of any dirt by
lightly tapping it. Then brush away any loose particles with a
soft-bristle brush. This step can usually be avoided with the
use of a prelter.
3. Spray cleaner generously over entire lter and let soak for
10 minutes.
4. Thoroughly rinse the lter with regular tap water (avoid
high-pressure hoses). Flush from the inside out or clean side
to the dirty side to prevent dirt from entering the lter.
5. Let the lter air dry before oiling, do not use any method to speed up the drying process. Using
a blow dryer or compressed air can cause the lter to disgure which would then allow particles
to pass through the lter.
PART 2, OILING THE FILTER:
1. Apply a small amount of oil to the soft bristle brush and spread the oil over the lter. Be sure to
apply a small amount of force so not to damage the lter element.
2. Continue applying oil to the lter using a soft bristle brush until the entire lter is covered in an
even amount of oil, just enough to give the lter a solid blue color. Apply enough oil to make the
lter a solid and uniform blue, but do not go beyond that.
3. Allow oil to sit for 20 minutes. Re-oil any dry spots that appear. Do not oil lter excessively. Exces-
sive oiling can cause damage to intake sensors.