User`s guide

4-29
Notes on Creating the Virtual Drive
The HDDs configuring the disk group should have the same capacity and rotation speed.
Be sure to execute a Consistency Check after the creation of a VD.
When installing an OS in the VD under the Onboard RAID Controller (MegaRAID ROMB), create a VD
dedicated to the OS installation.
WebBIOS cannot be handled via the remote console functions of NEC DianaScope.
The physical drive numbers shown in WebBIOS and those shown in the Universal RAID Utility are identified
as follows.
WebBIOS
Enclosure number and slot number shown in Physical Drives box*
* "X:X:X" shown in the Physical Drives box represents
Connector number:Enclosure number:Slot number.
With this server, the Connector number is not supported, thus, it is always indicated as "()". The Enclosure
Number is always "1". The Slot number (0 to 7) represents the slot number of the 2.5-inch hard disk
drive bay.
Universal RAID Utility
Enclosure number and slot number shown in Physical Device Properties
Note that the slot numbers shown in the Physical Drives box of WebBIOS are represented by the 0-origin
numbers, but those in the Universal RAID Utility are 1-origin numbers.
Physical Drives View of WebBIOS
Property of Physical Device in Universal RAID Utility