User`s guide
4-12
Console Redirection Submenu
Option Parameter Description Your Setting
BIOS Redirection
Port
[Disabled]
Serial Port A
Serial Port B
Specifies the address/interrupt of the
serial port to which a remote console
is connected.
Baud Rate 9600
[19.2K]
38.4K
57.6K
115.2K
Specifies the baud rate used for the
interface with successive remote
consoles.
Flow Control None
Xon/Xoff
[CTS/RTS]
CTS/RTS+CD
Specifies the flow control method.
Terminal Type PC ANSI
[VT100+]
VT-UTF8
Specifies the remote console type.
Continue
Redirection after
POST
Disabled
[Enabled]
Specifies whether to continue the
console redirection feature once the
POST is completed.
Remote Console
Reset
[Disabled]
Enabled
Enables or disables resetting by an
Escape command (Esc R) sent from
the remote console.
[ ]: Factory-set