User`s guide
3-4
SELECTING A SITE
Read the following precautions before selecting a suitable site for your server. The following describes the installation
and connection of the server.
CAUTION
Observe the following instructions to use the server safely. Failure to follow
these instructions may cause a fire, personal injury, or property damage. See
pages 1-3 to 1-8 for details.
Never attempt to lift the server only by yourself.
Do not install the server in any place other than specified.
The following figure illustrates a site suitable for installing the server.
* We recommend using the
server in a room in chich
temperature ranges between
15 and 25ºC.
Close enough to connect
the mouse and the display.
Install the server on the
floor or on a rigid, flat
desk.
Open the stabilizers
to secure the server.
Place having a space enough to fully
open the front door (The front door
extrudes about 35 mm from the left
side of the server when fully opened.)
Room that satisfies the following conditions: *
<While operating> <While halting>
Temperature: 10 to 35ºC 5 to 40ºC
Humidity: 20 to 80% 10 to 80%
Temperature gradient: ±10ºC/h ±15ºC/h
Atmos
p
here
(
h
p
a
)
: 749 to 1040 749 to 1040 h
p
a
100 to 120 Vac/200 to
240 Vac parallel
bi-polar wall power
grounded outlet.
Wall outlet to
connect the
supplied power
cord.
UPS to prevent momentary
voltage drop due to power
failure or lightning *
* Optional. UPS is
recommended for best
use of features of server.
Allow clearance of at
least 150 mm in the front
and the rear of the server.