10-3
Installing an Internal SCSI File Device
To install an internal SCSI file device, you need to prepare a SCSI controller and SCSI cable.
IMPORTANT:
Up to two SCSI devices can be installed in the server.
To install two half-height SCSI devices in the 5.25-inch device bay, move the
factory-installed optical disk drive to the top bay.
The internal SCSI cable approved by your manufacturer is equipped with a terminator. Set to "Disabled" all the
terminators of the connected devices. For other settings, refer to the manual provided with the device.
The SCSI transfer rate, among other settings, must be se on a file device. Refer to the manual provided with the SCSI
controller.
Motherboard
PCIe #5
PCIe #4
PCIe #3
PCI #2
PCI-X #1
SAS cable SCSI cable IDE cable
SCSI controller
(SCSI device)
(IDE device)
Optical disk drive
5.25-inch
device bay
3.5-inch hard
disk drive bay
Hard disk drives
are optional.
PCIe #6
IDE
ID3
ID2
ID1
ID0
Internal RAID
controller
Termin ator
Internal SCSI cable