User`s guide
9-33
Change setting of jumper switch on motherboard
For correct operation of the water-cooled heat sink, you must change the setting of the jumper switch (CN6) on the
motherboard.
Connect cables
Connect the cable of the water-cooled heat sink to the connector on the motherboard.
Check the connector number indicated on the cable and the indications on the motherboard for proper connection.
Water-cooled heat sink for CPU1
Connect cable P1 to connector FAN5.
Connect cable P2 to connector FAN1.
Water-cooled heat sink for CPU2 (when two processors are installed)
Connect cable P1 to connector FAN6
Connect cable P2 to connector FAN4.
Install the dummy cover
If only one processor is installed, replace the dummy cover of CPU2 with the one provided with the water-cooled heat
sink.
CPU1 ↔ P1 ↔ FAN5
CPU1 ↔ P2 ↔ FAN1
CPU2 ↔ P1 ↔ FAN6
CPU2 ↔ P2 ↔ FAN4
Jumper switch setting
Standard
heat sink
Water-cooled
heat sink