User`s guide
9-31
Installation of Water-cooled Heat Sink
Prepare a Phillips screwdriver for installation. The screwdriver must be magnetized.
Precautions
1. Before starting the installation, be sure to power off the server and unplug the power cord from the outlet.
This is required to prevent personal injury and device failure.
2. Remove the side cover and other components according to the User Guide of the server.
Preparation
Removal of CPU duct and heat sink
Remove the factory-installed CPU duct. The factory-installed heat sink is an air-cooled type.
1. Loosen the screw that secures the heat sink with Phillips screwdriver.
If the heat sink is stuck to the processor, twist the heat sink horizontally to remove it.
2. If the cooling sheet remained on the processor surface after you removed the heat sink, scrape it with a ruler
or the like.