User`s guide
8-21
Problems with Express Setup
The following message appeared when you tried to install Express Setup to a hard disk drive that has a smaller
capacity than the specified partition size:
The creating of the partition was failed.
The process can not be continued. The process was stopped.
O K
→ Cannot continue the setup.
Specify a smaller partition size than the capacity of the connected hard disk drive, and then retry the
setup.
The Express Setup terminated and asks to input setup information.
→ There are some errors on the specified setup information.
Follow the instructions to input a correct value. It is not necessary to cancel the installation.
The created system partition is of a smaller size than the specified value.
→ With Express Setup, in some cases the size of the created system partition is about 8MB smaller than the
specified size.
It is not a problem for system operation.
Specified to join the Domain, but the system is installed as Workgroup.
→ When the setup fails to join the Domain during the installation, it will install the system as a Workgroup.
Open [System] in Control Panel to specify joining the Domain.
Changed the giga driver speed from 1000M bps to 100M bps. But the changed speed is not properly displayed in
Network Details of NEC ESMPRO DataViewer (still 1000M bps is indicated):
→ It does not affect the operation of the LAN driver.
Fail to start the Parameter File Creator:
The Parameter File Creator requires to be un by "Microsoft® HTML Application host".
If the Parameter File Creator does not start, associate the file type with "Microsoft® HTML Application
host" via following process.
1) Click [Run] on Start menu.
2) Type "%windir%\system32\mshta.exe /register" in the [Open] box, and click [OK].