User`s guide

8-12
Error
code
Error message Recommended Action
0B8B BMC progress check timeout.
0B8C BMC command access failed.
0B8D Could not redirect the console - BMC Busy -
0B8E Could not redirect the console - BMC Error -
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90 BMC Platform Information Area corrupted.
0B91 BMC update firmware corrupted.
Turn off the power once and then on again to start the
server. If it does not correct the error, contact your
service representative.
0B92 Internal Use Area of BMC FRU corrupted.
This is not a fatal error. Turn off the power once and then
on again to restart the server. If it does not correct the
error, contact your service representative.
0B93 BMC SDR Repository empty.
Turn off the power once and then on again to restart the
server. If it does not correct the error, contact your
service representative.
0B94 IPMB signal lines do not respond.
0B95 BMC FRU device failure.
This is not a fatal error. Turn off the power once and then
on again to restart the server. If it does not correct the
error, contact your service representative.
0B96 BMC SDR Repository failure.
0B97 BMC SEL device failure.
0B98 BMC RAM test error.
0B99 BMC Fatal hardware error.
Turn off the power once and then on again to start the
server. If it does not correct the error, contact your
service representative.
0B9A BMC not responding.
Update the RMC firmware. If it does not correct the
error, contact your service representative.
0B9B Private I2C bus not responding.
0B9C BMC internal exception.
0B9D BMC A/D timeout error.
0B9E SDR repository corrupt.
0B9F SEL corrupt.
Turn off the power once and then on again to start the
server. If it does not correct the error, contact your
service representative.
0BB0 SMBIOS – SROM data read error. Contact your service representative.
0BB1 SMBIOS – SROM data checksum bad.
8010 The error occurred during water cooling unit
sensor reading.
8012 Water pump #n out of the range.
8068 Unsupported Processor Speed detected on
CPU Slot 1.
8069 Unsupported Processor Speed detected on
CPU Slot 2.
8150 NVRAM Cleared by Jumper Start SETUP and provide the settings again.
8151 Password Cleared by Jumper Start SETUP and set the password again.
8160 Mismatched Processor Type/Speed detected
on Processor 1.
Contact your service representative.
8161 Mismatched Processor Type/Speed detected
on Processor 2.
None Expansion ROM not initialized – PCI Mass
Storage Controller in slot xx (xx: slot
number)
Disable the initialization of the optional device expansion
ROM by using the BIOS SETUP utility (see Chapter 4).