User`s guide

User Guide
148
www.bull.com
Fix Hard Disk Drives
Installing a Fixed Hard Disk Drive
Up to six SATA or 4 SCSI fixed hard drives can be installed in the fixed hard drive cage. Power
requirements for each individual hard drive may limit the maximum number of drives that can be
integrated into the server chassis.
Caution
Fixed drives are NOT hot swappable. Before removing or
replacing the drive, you must first take the server out of service,
turn off all peripheral devices connected to the system, turn off
the system by pressing the power button, and unplug the AC
power cord from the system or wall outlet.
Warning
Drive bay slots 1, 3, and 5 MUST be populated first. Failure to
do so could result in thermal issues within the chassis.
Figure 52: Drive Bay Slot Order
(SAS/SATA drives illustrated.)
AF000316
1
2
4
3
5
6