User`s guide

User Guide
124
www.bull.com
Manual Rebuild
1. Replace a hard disk drive and power on the server.
2. Run the LSI Logic Software RAID Setup Utility.
3. Select Rebuild from the Top menu.
The Rebuild – Physical Drives Selection Menu screen appears.
Figure 41: Rebuild – Physical Drives Selection Menu
4. Move the cursor onto the hard disk drive displaying "FAIL" and then press
Space to select it.
Several hard disk drives can be selected (simultaneous rebuilding.)
5. The Fail indication for the selected hard disk drive starts blinking.
6. Once the hard disk drive is selected, press F10 to start rebuilding.
7. Press Yes when prompted to do so. The rebuild process starts.
When the progress bar in the Rebuild Physical Drives in Progress screen
reaches 100%, the rebuilding is completed.
8. Press Esc to return to the Top menu and exit the LSI Logic Software RAID
Setup Utility.
Replace a hard disk drive
Run the LSI Logic Software RAID Setup Utility
Execute the rebuilding
Exit the LSI Logic Software RAID Setup Utility