Refer to the release notes for further information on using SELVIEW.
SYSCFG
The SYSCFG command-line utility is used to configure the IP address and user
credentials of the BMC. Although Windows and Linux versions of this utility are
provided, their command syntax is the same.
Refer to the System Configuration Utility User Guide found on the ExpressBuilder
DVD for further details of each command.
Execute the following commands (in bold) to change the required parameters.
Note:
•
These commands must be run from the directory containing the
SYSCFG.EXE program.
• Entering some commands may produce an error, caused by the BMC
being too busy at that time to respond. Re-enter the command a few
seconds later.
Reset BMC
Restore the factory default BMC settings:
Command:syscfg /rfs
Reset the BMC:
Command:syscfg /rbmc
Note: Wait 10 seconds before entering further configuration commands.
IP address Configuration
Note: The IP address of the BMC operates independently of any operating
system IP address and must be unique to avoid conflicts.