User`s guide

User Guide
88
www.bull.com
6. Press Esc to return to the Top menu and exit the LSI Logic Software RAID
Setup Utility.
Caution:
Be sure to execute a Check Consistency after creating a configuration.
Check Consistency has two modes: "check and recover" and "check
only".
Others Operations
Clear Configuration
Clears the configuration information. Select Configure Clear Configuration from
the Top menu. Executing Clear Configuration clears all the configuration information
on the disk array controller and hard disk drives. The configuration information on all
the channels of the disk array controller is also cleared.
Note:
When the configuration information on the disk array controller and
that on the hard disk drive do not match (excluding at the replacement of
a faulty disk array controller), configuration may fail if you select the
configuration information on the disk array controller. In this case,
execute "Clear Configuration" to create the configuration again.
Use the MegaRAID Storage Manager to delete a specific logical drive.
Force Online
Puts online a hard disk drive being in the FAIL status.
Select Objects Physical Drive (select hard disk drive) Force Online from the
Top menu.
Rebuild Rate
Sets the Rebuild Rate.
Select Objects Adapter Sel. Adapter Rebuild Rate from the TOP menu.
The value range is 0% to 100%. The Default value (recommended) is 30%.
Hard disk drive information
Checks the hard disk drive information.
Select Objects Physical Drive (select hard disk drive) Drive Properties from
the Top menu.