User`s guide

User Guide
87
www.bull.com
7. Press Esc to return to the Top menu and exit the LSI Logic Software RAID
Setup Utility.
Figure 34: Objects - Physical Drive Selection Menu screen
Caution:
Select "Objects"
"Physical Drive"
"Port #X"
"Force Offline" to
cancel the hot spare setting.
When two or more hard disk drives (of the same capacity) are assigned
as hot spare, rebuilding starts with the one with the smaller CH number/
ID number.
Check Consistency
1. Run the LSI Logic Software RAID Setup Utility.
2. Select Check Consistency from the Top menu.
The Logical Drives screen appears.
3. Move the cursor onto the logical drive to be checked, and press Space to select
it.
4. Once the logical drive is selected, press F10 to start the consistency check.
5. When prompted to do so, press "Yes".
The consistency check starts.
When the progress bar in the Check Consistency Progress screen reaches
100%, the consistency check is completed.
Run LSI Logic Software RAID Setup Utility
Perform Check Consistency
Exit LSI Logic Software RAID Setup Utility