User`s guide

User Guide
84
www.bull.com
10. Once it is confirmed that the configuration has been saved, press Esc to return
to the Top menu screen.
11. On the Top menu screen, select Objects Logical Drive View/Update
Parameters to check the logical drive information.
12. Select Initialize in the Top menu screen.
13. When the Logical Drives screen appears, move the cursor to the logical drive
to be initialized, and press Space.
The logical drive is selected.
14. Press F10 to start the initialization, and press Yes when prompted to do so.
When the progress bar in the Initialize Logical Drive Progress screen reaches
100%, initialization is completed.
15. Execute a Check Consistency on the logical drive that has been initialized.
Refer to “Check Consistency” on page 87 for more information.
16. Press Esc to return to the Top menu and exit the LSI Logic Software RAID
Setup Utility.
Caution:
Be sure to execute a Check Consistency after creating a configuration.
Check Consistency has two modes: "check and recover" and "check
only".
Manual Rebuild
1. Replace a hard disk drive and power on the server.
2. Run the LSI Logic Software RAID Setup Utility.
Replace a hard disk drive
Run the LSI Logic Software RAID Setup Utility
Execute the rebuilding
Exit the LSI Logic Software RAID Setup Utility