6. Push the DIMM to the socket straight.
Figure 58: Pushing the memory to the socket
Note:
•
Make sure of the orientation of DIMM. The terminal side of the DIMM
has key and key slot to prevent incorrect insertion.
• Use extreme care when installing a DIMM. Applying too much pressure
can damage the socket.
7. Close the levers securely.
8. Install the left side cover you have removed.
9. Turn on the power of the server. Make sure that no error message appears in the
POST.
10. If POST displays an error message, take a note on the message and see the
POST error messages listed in “POST Error Messages” on page 163.
11. Run the BIOS SETUP and select [Advanced] ® [Memory Configuration] to
verify that the installed DIMM shows the status "Normal". Refer to
“Advanced Menu” on page 174 for details.
12. Select "Yes" for [Reset Configuration Data] on the [Advanced] menu.
This is required to update the hardware configuration information. Refer to
“Advanced Menu” on page 174 for details.
Note: The amount of installed memory will be automatically detected by the
system.