User`s guide
2-14 General Description
Hard Disk Drive LED
The disk LED located on the drive carrier indicates the following depending on the status:
Disk LED
Disk LED
3.5-inch hard disk drive 2.5-inch hard disk drive
Flashing (green)
The LED indicates that the hard disk drive is being accessed.
On (amber)
The LED indicates a failure of a hard disk drive mounted in RAID System.
NOTE: Even if one (two hard disk drives in RAID6) of the hard disk drives fails in Logical Drive
(RAID1, RAID5, or RAID6), the server can continue operation. However, replace the hard disk
drive as soon as possible, and perform reconstruction (rebuild) processing. (The failing hard disk
drive can be replaced in hot swap mode.)
Flashing switching back and forth between green and amber
The LED indicates that reconstruction (rebuild) processing is being performed for the hard disk drive. (This flashing
does not indicate a failure.) When a failing hard disk drive is replaced in RAID System, the system automatically
rebuilds the data. (Auto-rebuild function) The LED switches back and forth between green and amber during rebuild
processing.
The LED goes off when the rebuild processing has terminated. It turns amber when the rebuild processing fails.