8-14 Troubleshooting
On-screen message Description
Proc1 VccpAlm XX
Proc2 VccpAlm XX
Voltage alarm occurred on processor #1 or #2.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
ChipSet T-Trip Forcedly powered off due to temperature alarm on chipset.
CPU1_DIMM U-Err Unrecoverable error occurred on one of DIMMs on CPU1 side.
CPU2_DIMM U-Err Unrecoverable error occurred on one of DIMMs on CPU2 side.
Processor 1 IERR
Processor 2 IERR
IERR occurred on processor #1 or #2.
SMI timeout SMI timeout occurred.
HDD 1 Fault
HDD 2 Fault
HDD 3 Fault
HDD 4 Fault
HDD 5 Fault
HDD 6 Fault
The system operates with HDD being degraded.
(Supported only when Internal RAID Controller or Onboard RAID
Controller (LSI Embedded MegaRAID™) is used.)
HDD 4 Fault through HDD 6 Fault are shown on 2.5-inch hard disk
model only.
Sys Fan 1R Alarm Sys Fan 1R alarm occurred.
Sys Fan 2R Alarm Sys Fan 2R alarm occurred.
Sys Fan 3R Alarm Sys Fan 3R alarm occurred.
Sys Fan 4R Alarm Sys Fan 4R alarm occurred.
Sys Fan 5R Alarm FSys Fan 5R alarm occurred.
Sys Fan 6R Alarm Sys Fan 6R alarm occurred.
Sys Fan 7R Alarm Sys Fan 7R alarm occurred.
Sys Fan 1F Alarm Sys Fan 1F alarm occurred.
Sys Fan 2F Alarm Sys Fan 2F alarm occurred.
Sys Fan 3F Alarm Sys Fan 3F alarm occurred.
Sys Fan 4F Alarm Sys Fan 4F alarm occurred.
Sys Fan 5F Alarm Sys Fan 5F alarm occurred.
Sys Fan 6F Alarm Sys Fan 6F alarm occurred.
Sys Fan 7F Alarm Sys Fan 7F alarm occurred.
VBAT Alm XX Voltage alarm in lithium battery occurred.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
WDT timeout Watchdog timer timeout error occurred.