User`s guide

Troubleshooting 8-13
Messages displayed on the lower line (BMC message)
When the following messages are displayed on the virtual LCD, restart your server by turning it off and on. If an error still
occurrs, contact your service representative for maintenance.
On-screen message Description
BB +1.5v Alm XX
BB +1.8v Alm XX
BB 1.8vsb Alm XX
BB +3.3v Alm XX
BB 3.3vsb Alm XX
BB +5.0v Alm XX
BB 5vsb Alm XX
BB +12v Alm XX
Processor1 P_Vtt Alm XX
Processor2 P_Vtt Alm XX
Processor1 1.5v Alm XX
Processor2 1.5v Alm XX
Baseboard 1.0vsb Alm XX
Baseboard 1.1v Alm XX
Baseboard 1.2vsb Alm XX
Voltage alarm occurred on the mother board.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
BB Temp1 Alm XX Mother board thermal error occurred.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
DUMP Request ! Dump switch is pressed.
OS shutdown Alm OS shutdown alarm occurred.
Power Unit 1 Alm Power unit #1 Failure occurred.
Power Unit 2 Alm Power unit #2 Failure occurred.
Proc Missing Processor is not found.
Proc 1 T-Trip
Proc 2 T-Trip
Thermal Trip occurred on processor #1 or #2. The system is forcibly
turned off.
Proc1 Therm % XX
Proc2 Therm % XX
CPU1_DIMM1 Tmp XX
CPU1_DIMM2 Tmp XX
CPU1_DIMM3 Tmp XX
CPU1_DIMM4 Tmp XX
CPU1_DIMM5 Tmp XX
CPU1_DIMM6 Tmp XX
CPU2_DIMM1 Tmp XX
CPU2_DIMM2 Tmp XX
CPU2_DIMM3 Tmp XX
CPU2_DIMM4 Tmp XX
CPU2_DIMM5 Tmp XX
CPU2_DIMM6 Tmp XX
FP Temp Alm XX
Processor #1 or #2 thermal error occurred.
XX=09: high temperature (fetal)
XX=07: high temperature (warning)
XX=02: low temperature (warning)