User`s guide
Maintenance 7-9
6. Select [Test and diagnostics].
Select [End-User Mode] and the system diagnostics starts. The diagnostics will be completed in approximately three
minutes. When the diagnostics is completed, the screen of the display changes as shown below:
Diagnostics tool title
Test window title
[Enter] Detail Information [ESC] Return to Enduser Menu
Test End
T
eDoLi (TEst & Diagnosis On Linux) Ver001.00 (Build020901.1.1m)
<System>
MEM Memory 16 count NormalEnd
CACHE Cache 49 count NormalEnd
<SCSI>
HDD_02:000 DK32DJ-36W 89 count NormalEnd
Start 10:06:58 End 10:09:58 Pass 000:03:00 TestTime 000:03:00
T
est End : NormalEnd 03 AbnormalEnd 00 ForceEnd 00
Test result
Test summary
window
Guide line
– Diagnostics tool title
Shows the name and version of the diagnostic tool.
– Test window title
Shows the progress of the diagnostics. "Test End" is displayed when the diagnostics completes.
– Test result
Shows the start, end, and elapsed time and completion status of the diagnostics.
– Guide line
Shows the details of the keys to operate window.
– Test summary window
Shows the results of each test that executed the diagnostics. Move the cursor and press the Enter key on the
cursor line to display the details of the test.
When an error is detected by the system diagnostics, the relevant test result in the Test summary window is
highlighted in red, and "Abnormal End" is displayed in the result on the right side.
Move the cursor to the test that detected the error, and press the Enter key. Record the error message that has been
output to the Detail Information screen and contact your service representative.