User`s guide

4-102 Configuring Your Server
CONFIGURING MOTHER BOARD JUMPERS
With the pre-installed SETUP utility, you can set desired passwords to protect the data stored in the server against access from
unauthorized users. If you forget the passwords, however, you may want to clear them. The following section describes how to
clear these passwords. You can also use the following procedure to clear the CMOS data in the server.
IMPORTANT:
Clearing the CMOS data resumes the factory-set configuration data.
After clearing CMOS, you must run the BIOS SETUP utility and execute the following menus
to reconfigure your mother board.
– Load Setup Defaults in the Exit menu
– Memory Retest of Memory Configuration in the Advanced menu
– Processor Retest of Processor Settings in the Main menu
Refer to "RAID System Configuration" described earlier in this chapter for RAID
configuration jumper setting.
Do not change any other switch settings. Any change may cause the server to fail or
malfunction.
To clear passwords or the CMOS data, use the jumper switch on the mother board of the server. The following figure illustrates
the jumper switch location.
Pin for protecting/
clearing the password
Clear
Protect
Pin for protecting/
clearing the CMOS
contents
Clear
Protect
Rear
Front
Mother board